Questions? 1-800-442-2581
or 1-616-784-1121
8:00am-5:00pm M-F (Eastern Time)
Share |
Air Circulator Fans
Air Doors/Air Curtains
Baseboard Space Heaters
Bathroom Fans
Blowers (Portable Utility)
Camp, Fish, Hunt & RV
Ceiling Fans (Commercial/Ind)
Church Baptistry Heaters
Clearance & Specials
Comfort Space Heaters
Construction Heaters
Controls & Transformers
Drum Blowers (Portable)
Evaporative Coolers
Floor Warming Mats/Cables
Garage & Shop Heaters
Garden & Outdoor Items
Hand Dryers (Washrooms)
Heaters & Accessories
Heating Cable & Mats
High Temp. Wire & Acces.
Industrial Heating Products
Infrared Radiant Heaters
Lighting & Flashlights
Loading Dock Fans
Manufacturers (Vendors)
Nichrome Wire Coils & Acc.
Patio Heaters (Radiant)
Pipe Trace Freeze Protection
Portable 120V Space Heaters
Portable 240V Space Heaters
Replacement Repair Parts
Roof & Attic Ventilators
Roof & Gutter Deicing Cable
Self-Regulating Roof Cable
Self-Regulating Pipe Trace
Snow & Ice Removal
Tapes (Adhesive)
Temperature Sensors
Thermostats & Accessories
Tools, Glue, Lights & Gear
Unit Heaters (Blower)
Wall Exhaust Fans
Wall Heaters (Fan-forced)
Wall Panel Convectors
Water Heaters (Tankless)
Whole House Fans
Item Code: EASY10004

Description:  ADKS-150 30 Foot 120V 150W Heat Cable

EasyHeat ADKS Series Kit of Roof and Gutter De-Icing Heat Trace Cable - 30 Feet Long - 150 Watt - Residential Grade - 120 Volt - 5 Watts per Foot with 6 Foot Power Cord and Plug and Roof Clips and Cable Spacers.


Typically in stock at vendor warehouse, call for delivery time

Condition:  New in box

Easy Heat


Click Images to Enlarge



Voltage: 120 Volt
Wattage: 150 Watt
Length: 30 Feet
Applications: Ice Melting
Roof and Gutter Deicing
Color: Black
Cable Type: Constant Watt
Manufacturer: Easy Heat
Included: De-icing Cable
Shingle Clips
Cable Spacers
Installation Instructions

Features of Easy Heat ADKS-150

Eliminate damage caused by ice dams.

The Easy Heat ADKS series roof and gutter de-icing heat trace cable is an easy to use, pre-terminated, constant wattage heat trace designed to prevent costly ice damage by preventing ice dam formation and promoting the free flow of melt water through gutters and downspouts. This product is for the sole intended use of preventing ice dams from forming on inclined roofs with tab shingles, in gutters and in downspouts. This roof de-icing cable is not intended for use as a snow-melting system to clear roof of ice and snow. Never install on a flat roof. Never install on combustible materials. Not suitable for use on metal roofs.

The ADKS kit includes a de-icing cable with a 6 foot long cold section and plug, roof clips, and cable spacers.

Even in below freezing weather, snow on the roof will often thaw because of heat from the sun and heat loss from the house through the roof. As this melted snow reaches the roof overhang it refreezes. Here there is no heat loss so the roof surface is much colder. As this melted snow refreezes again and again on the roof overhang, an ice dam is formed. Soon water backs up under shingles, and leaks into the house. ADKS roof de-icing cable prevents water and ice damage by providing a clear path for melting water. It keeps roof edges, gutters and downspouts ice-free.

When designing a roof and gutter de-icing system, it is important to know that the Easy Heat ADKS heat trace is not intended to completely eliminate snow and ice from the roof. It is simply designed to allow for the free flow of melt water off of the roof edge, down the gutter and downspouts, and finally away from the foundation of the structure. The heat trace cable length should be selected to allow for the cable to serpentine along the roof edge, drop down into and then down the gutter, and then finally exit through the downspout. This will allow for a complete path for the melt water to flow which will eliminate the costly ice dams from forming on the roof edge.

Customers Who Purchased This Item Also Purchased:
Item CodeDescriptionVendorQuantity
18900 Current Sensing Device
Wrap-On Co., Inc. #18900 - Detect Cable Operation By Observing Current Sensing Indicator Light - 120VAC @12Amps - 10ft Power Cord with Piggy Back Plug Design
CSK-12 19 Roof Clips 16 Spacers
Combination package of 19 Extra Roof Cable Clips & 16 Extra Roof Cable Spacers for EasyHeat ADKS Roof and Gutter De-Icing Heat Trace Cable
Easy Heat
RS-2 Roof Cable Deicing Control
EasyHeat Optional Roof Sentry for EasyHeat ADKS Roof and Gutter De-Icing Heat Trace Cable. Senses temperature and water (Controls 1 ADKS Cable) - 1200 Watt capacity at 120 VAC.
Easy Heat
Substitute Items:
Item CodeDescriptionVendorQuantity
088L3500 RX 30FT 120V 170W Heat Cable
120 Volt 30 Ft. 170 Watts 1.4 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
CWR150-30 30Ft 120V 150W Roof Heat
King Electric Pre-Terminated Roof & Gutter De-Icing Heating Cable Kit - 120 Volt - 150 Watts - 30 Foot Heated Length - 5 Watts/Foot - Power Cord/Plug - Roof Clips and Cable Spacers - Constant Wattage - Residential Grade
King Electric