088L3001 RX-C 50 Roof Clips


(50pcs in Bag)
UPC: 5703466239285
The Danfoss RX-C Roof Clips are suitable for use with the RX-C Self Regulating Cables. The clips are designed to secure the cables to asphalt shingles, metal seam roofs, and gutters.

Tools Required:
• pliers
• caulking gun
• adhesive (see below)

• Shingles must be clean and dry
• Note adhesive application temperature limits
• Allow proper cure time for adhesive (typically 24 hours)
• Not recommended for rubber/membrane roof
• Do not use screw/nail with clip
• Consult roofing supplier for recommended adhesives

Recommended Adhesives:
See roofing supply distributors for recommendations

1. Apply Adhesive:
• Apply 0.2 oz. of adhesive to back of clip.
• (Please note required application temperatures when applying glue.)

2. Press Clip to Roof Surface:
• Lift shingle & orient clip.
• Press down (ensure adhesive flows through holes).
• Do not trim back adhesive beads.
• Press shingle down.

3. Install Cables/Close Clamps
• Allow proper cure time (typically 24 hours- refer to adhesive.)
• Install RX-C de-icing cable.
• Use pliers to close clamps (ensuring not to damage cable).

Warning
• Roof clips must be installed properly to ensure proper operation and to prevent the risk of electrical hazard or fire. Follow all design, installation, assembly, and test instructions carefully.
• Arcing may not be stopped by conventional circuit protection.
• Do not use clip for installation on slate or tile roofs as damage may occur to roof material. Consult roofing manufacturer for components approved for use on specific roof material.
• De-energize all power circuits before installation or servicing.
• Keep ends of heating devices and kit components dry before and during installation.
• While using pliers to close clamps on heating cable, heating cable should not be crushed or altered structurally in any way.
• The cable should not be twisted during installation.
• Heating cable should not be embedded in the thermal insulation.















RX-C Roof Clip Data Sheet
Item CodeDescriptionVendorQuantity
MORSNOW10005
187086000084
SB-12 Surebond 10F Gray 24Hr Cure
10.3 Fl oz Tube Aluminum Gray Surebond Metalbond Sealant. For adhering plastic or metal roof clips to wood or metal (Steel, Aluminum or Galvanized) roofs. Application temperature above 10F - Cure time 24 Hours - 1200PSI Tensile Strength
Surebond
MORSNOW10006
087086000445
SB-170 Surebond -20F Clear 24Hr Cure
10.3 Fl oz Cartridge Clear Silicone Sealant. For adhering plastic or metal roof clips to wood or metal (Steel, Aluminum or Galvanized) roofs. Application temperature -20F to 122F
Surebond
MORSNOW10004
187086000244
SB-188 Surebond -20F Clear 24Hr Cure
10.3 Fl oz Tube Clear Surebond Silicone Sealant. For adhering plastic or metal roof clips to wood, metal and EPDM rubber roofs. Application temperature of -20F to 122F. Cure time 24 Hours - 325PSI Tensile Strength - 10-20 Minute Tack Free Time
Surebond
MORSNOW10003
187086000305
SB-190 Surebond 50F Translucent 28 Days
10.3 Fl Oz. Tube Translucent Surebond Adhesive Everseal Sealant. For adhering roof clips to metal roofs. Minimum application temperature of 50F. Cure time 28 days - 2000PSI Tensile Strength - 18-24 Hour Tack Free Time
Surebond