Questions? 1-800-442-2581
or 1-616-784-1121
8:00am-5:00pm M-F (Eastern Time)
Share |
Refine Results Clear All
Product Types
Air Vane Louver Kits
Built In Thermostat Kits
Ceiling Bracket
Fan Forced Heaters
Garage Heaters
Non Programmable Thermostats
Unit Heaters
Wall Bracket Hanging Arm
208 Volt
240 Volt
1 Phase
3 Phase
3750 Watt
5000 Watt
$0 to $25
$25 to $50
$250 to $500
$50 to $75
14 Inch
16 Inch
8.25 Inch
Product Types
Select Product Types Clear
 Accessories (5)
 Air Vane Louver Kits (1)
 Built In Thermostat Kits (2)
 Ceiling Bracket (1)
 Fan Forced Heaters (1)
 Garage Heaters (1)
 Non Programmable Thermostats (2)
 Unit Heaters (1)
 Wall Bracket Hanging Arm (1)
More... Show First 5 Values
Select Voltage Clear
 208 Volt (1)
 240 Volt (1)
Select Phase Clear
 1 Phase (1)
 3 Phase (1)
Select Wattage Clear
 3750 Watt (1)
 5000 Watt (1)
Select Price Clear
 $0 to $25 (2)
 $25 to $50 (2)
 $250 to $500 (1)
 $50 to $75 (1)
Select Width Clear
 14 Inch (1)
Select Height Clear
 16 Inch (1)
Select Depth Clear
 8.25 Inch (1)
Select Color Clear
 Almond (4)
 Black (2)
Select Vendors Clear
 Cadet (6)
Air Circulator Fans
Air Doors/Air Curtains
Baseboard Space Heaters
Bathroom Fans
Blowers (Portable Utility)
Camp, Fish, Hunt & RV
Ceiling Fans (Commercial/Ind)
Church Baptistry Heaters
Clearance & Specials
Comfort Space Heaters
Construction Heaters
Controls & Transformers
Drum Blowers (Portable)
Evaporative Coolers
Floor Warming Mats/Cables
Garage & Shop Heaters
Garden & Outdoor Items
Hand Dryers (Washrooms)
Heaters & Accessories
Heating Cable & Mats
High Temp. Wire & Acces.
Industrial Heating Products
Infrared Radiant Heaters
Lighting & Flashlights
Loading Dock Fans
Manufacturers (Vendors)
Nichrome Wire Coils & Acc.
Patio Heaters (Radiant)
Pipe Trace Freeze Protection
Portable 120V Space Heaters
Portable 240V Space Heaters
Replacement Repair Parts
Roof & Attic Ventilators
Roof & Gutter Deicing Cable
Self-Regulating Roof Cable
Self-Regulating Pipe Trace
Snow & Ice Removal
Tapes (Adhesive)
Temperature Sensors
Thermostats & Accessories
Tools, Glue, Lights & Gear
Unit Heaters (Blower)
Wall Exhaust Fans
Wall Heaters (Fan-forced)
Wall Panel Convectors
Water Heaters (Tankless)
Whole House Fans
You searched for: Cadet CEH. Industrial Fan Forced Unit Heater. 208/240 Volts. 5,000/3,750 Watts
Results Displayed: 1 - 6 of 6

Cadet CEH. Industrial Fan Forced Unit Heater. 208/240 Volts. 5,000/3,750 Watts

Calculate the heat loss of the area to be heated. It is recommended that one of the following methods be used: ASHRAE Guide and Data Book (The American Society of Heating, Refrigeration & Air Conditioning Engineers); The NEMA Handbook (The National Electrical Manufacturer's Association); or the ACCA Manual J (The Air Conditioning Contractors of America). The layout of the space to be heated must be taken into consideration to determine the selection of the best size heater and air displacement. Most applications benefit from a combination of vertically and horizontally discharged air delivery. In buildings with large doors that are frequently opened, use a high velocity heater with horizontal air flow across the opening, or use an infrared heater. In smaller areas where comfort is a prime consideration, more heaters of smaller capacity are recommended. Smaller KW heaters are also recommended for low mounting heights to avoid discomfort and increased noise levels. Additionally, there is better air distribution by using a greater number of lower KW heaters.


  • Manual reset thermal protection

  • - Commercial grade high temperature manual reset
  • High mass, tubular element for long life

  • Fan delay eliminates cold draft on startup and disperses residual heat on shutdown

  • Rugged die formed construction for durability

  • Wire single or three phase to suit the application

  • Mounts vertically or horizontally

  • UL Listed

  • Horizontal Air Flow – Position heaters to allow the air flow to "wipe" the exposed walls without blowing directly against the wall. Spacing between the heaters should be approximately 1.5 times the "air throw" of the heaters (approx. air throw is 12').

    Vertical Air Flow – When vertical discharging heaters are used exclusively, the air streams must overlap to blanket outside walls and provide good heat distribution. Vertical air flow is best used for areas with high ceilings or bays. Vertical discharging units are to be mounted high above machinery, assembly lines, etc. Vertical discharging units are best used when the perimeter heat loss is adequately controlled.

    Ordering Information:
    Model CEH005-P, (1 Phase) is designed to use a C600M, C600S or a CEKTB2 thermostat. If you add the jumpers, as shown on the heater wiring diagram (supplied with instructions and in wiring compartment) you can use a Single Pole 22 amp wall stat or a CEKTB1 thermostat. USE ONLY C600M, C600S, OR A CEKTB2 FOR 3 PHASE hookup on this model.

    Approximate air throw is 12'. The CEH is recommended for elevations under 7500 feet

    Architectural Information:
    Fan forced unit heater shall be UL Listed and dual rated at 208/240 Volts. Horizontal or vertical mounting shall be possible to direct discharged air. External cabinet shall be constructed of 20 gauge high quality steel. All metal surfaces of the cabinet, external and internal, shall be finished with a baked on powder coat paint system. Fan shall be aluminum blade axial flow type, and mounted directly to the motor shaft. Motor shall be shaded pole, industrial rated, with an inherent overheating protection device. Heating elements shall be sealed in magnesium oxide powder and protected by metal sheathing, over which aluminum fins are applied. Heater shall be equipped with manual reset thermal cut out for over temperature protection. Fan motor circuit shall be thermostatically controlled, allowing fan to remain operating after the elements have shut off, discharging the residual element heat. Wiring compartment shall have convenient access door with captured hardware.

    Product Dimensions: 16"H x 14"W x 8.25"D

    Cadet Owner's Guide
    Cadet Specification Sheet
    Item CodeDescriptionVendorQuantity
    CEKWM CEH Series Almond Wall Hanger Arm
    Cadet Wall Mounting Bracket Hanging Arm for CEH Series Unit Heater - also requires CEKM1 - Wall Arm & Bolt/Nut/Washer combo to attach to CEKM1
    CEKM1 CEH Series Ceiling Hat Bracket
    Cadet Ceiling Mount Hat Bracket - Bolts or screws to top of CEH style unit heater or CEKWM Wall Arm for Mounting - Powder Coat Black Paint
    CEKTB2 CEH Series 2-Stage Thermostat Kit
    Cadet Integral Field Mount Kit - Mounts through knockout on front of CEH model heater for dial control - includes Almond control knob, wiring instructions and mounting screws - 22 Amps at 240 V
    CEKTB1 CEH Series 1P Thermostat Kit
    Cadet Single Pole Integral Field Mount Kit - Mounts through knockout on front of CEH model heater for dial control - includes Almond control knob, wiring instructions and mounting screws - 120/240V
    CEKV1 CEH Series Air Vane Louver Kit
    Cadet 5 Almond Air Vanes & Springs for each - Replaces diffuser that comes standard on all CEH Series Unit Heaters
    CEH005-P 240/208V Industrial Unit Heater
    Cadet CEH 1/3 Phase - 5000 Watts at 240 volts or 3750 Watts at 208 volts - Garage/Shop or Smaller Industrial Area Heater - Almond Color