Questions? 1-800-442-2581
or 1-616-784-1121
8:00am-5:00pm M-F (Eastern Time)
 
 
Share |
 
Refine Results Clear All
Product Types
Fan Forced Heaters
Wall Heaters
Voltage
208 Volt
Phase
1 Phase
Wattage
1000 Watt
1250 Watt
1500 Watt
1750 Watt
2250 Watt
500 Watt
750 Watt
Price
$150 to $250
Width
13.625 Inch
Height
10.375 Inch
Depth
4 Inch
Color
Bright White
Vendors
King Electric
Product Types
Select Product Types Clear
 Fan Forced Heaters (1)
 Wall Heaters (1)
Voltage
Select Voltage Clear
 208 Volt (1)
Phase
Select Phase Clear
 1 Phase (1)
Wattage
Select Wattage Clear
 1000 Watt (1)
 1250 Watt (1)
 1500 Watt (1)
 1750 Watt (1)
 2250 Watt (1)
 500 Watt (1)
 750 Watt (1)
More... Show First 5 Values
Price
Select Price Clear
 $150 to $250 (1)
Width
Select Width Clear
 13.625 Inch (1)
Height
Select Height Clear
 10.375 Inch (1)
Depth
Select Depth Clear
 4 Inch (1)
Color
Select Color Clear
 Bright White (1)
Vendors
Select Vendors Clear
 King Electric (1)
$25 or Less Products
Baseboard Space Heaters
Camp, Fish, Hunt & RV
Church Baptistry Heaters
Clearance & Specials
Comfort Space Heaters
Construction Heaters
Controls & Transformers
Cooling/Air Conditioning
Fans/Blowers/Ventilation
Floor Warming Mats/Cables
Garage & Shop Heaters
Garden & Outdoor Items
Hand Dryers (Washrooms)
Heaters & Accessories
Heating Cable & Mats
High Temp. Insulation
High Temp. Wire & Acces.
Industrial Heating Products
Infrared Radiant Heaters
Lighting & Flashlights
Manufacturers (Vendors)
Nichrome Wire Coils & Acc
Patio Heaters (Radiant)
Pipe Freeze Protection
Portable Space Heaters
Replacement Repair Parts
Roof & Gutter Deicing
Snow & Ice Removal
Tapes-Fiberglass/Aluminum
Temperature Sensors
Thermostats & Accessories
Tools, Instruments & Gear
Unit Heaters (Blower)
Wall Heaters (Fan-forced)
Wall Panel Convectors
Water Heaters (Tankless)
ITEM # QTY.
Results
You searched for: SL Series 208 Volt Wall Heaters
Results Displayed: 1 - 1 of 1
The Slim Line heater was specifically designed as an easy replacement for baseboard heaters. This is achieved by using a slim,
surface mounted wall can that can be mounted down at floor level, unlike all other fan heaters that are required to be installed at least 4" above the floor.

The Pic-A-Watt® feature easily allows adjustment to the proper baseboard replacement size. For example: 2ft = 500W, 3ft = 750W, 4ft = 1000W, 5ft = 1250W, 6ft = 1500W, 8ft = 1750W, and 10ft = 2250W. Same quiet design as the PAW heater in an easy to install package. Just remove the old baseboard and wall mount the Slim Line heater. Use a wall thermostat or built-in thermostat kit.




* Pic-A-Watt® Element
* C-Frame Motor
* Squirrel Cage Blower
* Surface Mount
* Multiple Wattage
* 20 Gauge Powder Coated Grill with contemporary die formed round corners.
* Standard Color - Bright White
* Bi-Metallic Limit trips and automatically resets or is manually reset by the thermostat
* Optional 1-Pole or 2-Pole unit mount thermostat 45°-80°F


Ratings: Heaters shall be available in wattages of 250 to 2,250, at 120, 208, 240, or 277 volts. The heater shall be approved for surface mounting with zero clearance from the floor.

Blower and Motor: A tangential cylindrical blower, delivering 65 CFM, shall be driven by a shaded pole, permanently lubricated, C-frame type motor with impedance protection and sealed bearings. Motors shall be the same voltage as the heater.

Elements: Elements assemblies shall be non-glowing design. Element assemblies shall consisting of three steel sheathed heating tubes in a furnace brazed, plate finned, block design. Each sheathed tube shall contain coiled Ni-Chrome wire, embedded in an insulator of magnesium oxide. The element assembly shall provide a minimum of seven (7) possible wattage configurations available for selection during field installation. The use of external resistors, diodes, or other weak links to obtain multiple wattages will not be acceptable.

Thermal Overload: Heaters shall be equipped with thermal overload protection, which disconnects elements in the event normal operating temperatures are exceeded. The thermal overload protection device shall automatically reset when normal operating temperatures are reached or manually reset by the thermostat.

Surface Can: The surface can shall be 20 gauge electro-galvanized steel and shall contain a minimum of three (3) knockouts
through which power leads are brought. The surface can shall be epoxy powder coated, and contain a stranded grounding wire.
Minimum Clearance to Floors and Sidewalls.

Grill: The grill shall be louvered, one piece design with rounded edges on all four sides, with rounded corners to prevent snags
with other materials. The grill shall be epoxy powder coated in the color specified on the plans.

Approval: Heaters shall be listed and approved by a nationally recognized testing laboratory to UL standards.














Catalog Page
Installation Instructions
Item CodeDescriptionVendorQuantity
KINGELECTRIC19555
SL2022 King Electric Wall Heater
King Electric Wall Heater - SL (Slim Line) Series - 208 Volt With Field Selectable Wattages of 500/750/1000/1250/1500/1750/2250 Watt - Includes Bright White Colored Surface Mounted Wall Can and Grill
King Electric