Questions? 1-800-442-2581
or 1-616-784-1121
8:00am-5:00pm M-F (Eastern Time)
 
 
Share |
 
Air Circulator Fans
Air Doors/Air Curtains
Baptistry Heaters for Churches
Baseboard Space Heaters
Bathroom Fans
Blowers (Portable Utility)
Camp, Fish, Hunt & RV
Ceiling Fans (Commercial/Ind)
Clearance & Specials
Comfort Space Heaters
Construction Heaters
Controls & Transformers
Drum Blowers (Portable)
Evaporative Coolers
Fans/Blowers/Ventilation
Floor Warming Mats/Cables
Garage & Shop Heaters
Garden & Outdoor Items
Hand Dryers (Washrooms)
Heaters & Accessories
Heating Cable & Mats
High Temp. Wire & Acces.
Industrial Heating Products
Infrared Radiant Heaters
Lighting & Flashlights
Loading Dock Fans
Manufacturers (Vendors)
Nichrome Wire Coils & Acc.
Patio Heaters (Radiant)
Pest/Bird/Animal/Insect Control
Pets/Farms/Ponds/Ranches
Pipe Cable (Constant Wattage)
Pipe Cable (Self-Regulating)
Pipe Trace Freeze Protection
Portable 120V Space Heaters
Portable 240V Space Heaters
Replacement Repair Parts
Roof & Attic Ventilators
Roof & Gutter Deicing Cable
Roof Cable (Constant Wattage)
Roof Cable (Self-Regulating)
Snow & Ice Removal
Tapes (Adhesive)
Temperature Sensors
Thermostats & Accessories
Tools, Glue, Lights & Gear
Unit Heaters (Blower)
Wall Exhaust Fans
Wall Heaters (Fan-forced)
Wall Panel Convectors
Water Heaters (Tankless)
Whole House Fans
ITEM # QTY.
Results
You searched for: DanFoss RX Series Roof & Gutter Electric Constant Watt De-Icing Heating Cable Kits with Shingle Clips & Spacers
Results Displayed: 1 - 19 of 19

DanFoss RX Series Roof and Gutter De-Icing Cable



 


Description


Danfoss RX kits provide the protection needed to prevent ice dams and build-up from damaging building and gutters.


Each kit Contains The Following:



  • Heating cable 120 VAC, 5 Watt/Ft

  • Power Lead, 6 Ft Long with Heavy Duty Grounded Plug

  • Shingle Clips

  • Instruction Manual


 


Specifications



  • Type - Twin Conductor, Constant wattage

  • Voltage - 120 VAC

  • Output - 5 Watt/Ft

  • Length - Various Lengths Available From 30ft to 265ft

  • Wire Insulation - TeflonTM FEP and XLPE

  • Filler Sheath - PEX Polyethylene

  • Outer Sheath - PVC

  • Maximum Rated Temperature - 220°F (105°C)

  • Bending Radius - Minimum 1.5 Inch (38mm)

  • Diameter - ¼ Inch (6mm)

  • Power Lead Length - 6 Ft (1.82m)


















Danfoss RX Roof and Gutter Deicing Cable Data Sheet
Danfoss RX Roof and Gutter Deicing Cable Installation Instructions
Danfoss RX Roof and Gutter Deicing Cable Specification Sheet
Danfoss RX1200 Roof and Gutter Control Data Sheet
Danfoss RX1200 Roof and Gutter Control Installation Instructions
Danfoss RX1200 Roof and Gutter Control Specification Sheet
Item CodeDescriptionVendorQuantity
DANFOSS088L0024
5703466152720
088L0024 RX Roof Clip Type A 25pc. Bag
Danfoss Roof Clip Type A for Danfoss RX Kits
Danfoss
DANFOSS088L3002
5703466175279
088L3002 Downspout Edge Protection Plate
Danfoss Downspout Hanger Bracket used to provide mechanical protection to the roof & gutter deicing heating cable as it goes over sharp edges and to hold the heating cable in place at the top of downspouts
Danfoss
DANFOSS088L3003
5703466164488
088L3003 RX Roof Clips Type B 20 pc. Bag
Danfoss RX Roof Clips Type B
Danfoss
DANFOSS088L3004
5703466164006
088L3004 RX Spacer Clips 10pc Bag
Danfoss RX Kit Spacer Clips - 10pcs/bag
Danfoss
DANFOSS088L3005
5703466162927
088L3005 RX Shingle Clips 25pc Bag
Danfoss RX Kit Shingle Clips - 25pcs/bag
Danfoss
DANFOSS088L3012
5703466242599
088L3012 RX Shingle Clips 25pc Bag
Danfoss RX Kit Shingle Clips - 25pcs/bag
Danfoss
DANFOSS088L3500
5703466162033
088L3500 RX 30FT 120V 170W Heat Cable
Danfoss 120 Volt 30 Ft. 170 Watts 1.4 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L3502
5703466162057
088L3502 RX 65FT 120V 310W Heat Cable
Danfoss 120 Volt 65 Ft. 310 Watts 2.6 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L3503
5703466162064
088L3503 RX 80FT 120V 390W Heat Cable
Danfoss 120 Volt 80 Ft. 390 Watts 3.3 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L3504
5703466162071
088L3504 RX 100FT 120V 450W Heat Cable
Danfoss 120 Volt 100 Ft. 450 Watts 3.8 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L3505
5703466162088
088L3505 RX 120FT 120V 535W Heat Cable
Danfoss 120 Volt 120 Ft. 535 Watts 4.5 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L3508
5703466162118
088L3508 RX 170FT 120V 760W Heat Cable
Danfoss 120 Volt 170 Ft. 760 Watts 6.3 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L3510
5703466162132
088L3510 RX 230FT 120V 1080W Heat Cable
Danfoss 120 Volt 230 Ft. 1080 Watts 9.0 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L3511
5703466162149
088L3511 RX 265FT 120V 1220W Heat Cable
Danfoss 120 Volt 265 Ft. 1220 Watts 10.2 Amps - Kit Includes: Professional Grade Roof and Gutter Heating Cable - Pre-Terminated Industrial Strength AC Plug - Shingle Clips - Spacer Clips - Full Two Year Warranty
Danfoss
DANFOSS088L9000
5703466241271
088L9000 RX1200 Roof & Gutter Control
Danfoss De-Icing Controller - 10.2 Amps - 120 Volts - 1225 Watts - On at 39.2F Off at 44.6F - Power & Heating Indicators - 4.9ft 16AWG Black Power Cord & grounded plug - 2.3ft Black Probe Lead - 9.84ft Black Moisture Sensor Wire - 6 Sensor Shingle Clips
Danfoss
MORSNOW10003
187086000305
SB-190 Surebond 50F Translucent 28 Days
10.3 Fl oz Tube Translucent Surebond Adhesive Everseal Sealant. For adhering roof clips to metal roofs. Minimum application temperature of 50F. Cure time 28 days - 2000PSI Tensile Strength - 18-24 Hour Tack Free Time
Surebond
MORSNOW10004
187086000244
SB-188 Surebond -20F Clear 24Hr Cure
10.3 Fl oz Tube Clear Surebond Silicone Sealant. For adhering plastic or metal roof clips to wood, metal and EPDM rubber roofs. Application temperature of -20F to 122F. Cure time 24 Hours - 325PSI Tensile Strength - 10-20 Minute Tack Free Time
Surebond
MORSNOW10005
187086000084
SB-12 Surebond 10F Gray 24Hr Cure
10.3 Fl oz Tube Aluminum Gray Surebond Metalbond Sealant. For adhering plastic or metal roof clips to wood or metal (Steel, Aluminum or Galvanized) roofs. Application temperature above 10F - Cure time 24 Hours - 1200PSI Tensile Strength
Surebond
MORSNOW10006
087086000445
SB-170 Surebond -20F Clear 24Hr Cure
10.3 Fl oz Cartridge Clear Silicone Sealant. For adhering plastic or metal roof clips to wood or metal (Steel, Aluminum or Galvanized) roofs. Application temperature -20F to 122F
Surebond