Questions? 1-800-442-2581
or 1-616-784-1121
8:00am-5:00pm M-F (Eastern Time)
 
 
Share |
 
Refine Results Clear All
Product Types
Accessories
Snow Melting Controllers
Price
$1000 +
$150 to $250
Vendors
ETI
Product Types
Select Product Types Clear
 Accessories (1)
 Snow Melting Controllers (3)
Price
Select Price Clear
 $1000 + (2)
 $150 to $250 (1)
Vendors
Select Vendors Clear
 ETI (3)
Air Circulator Fans
Air Doors/Air Curtains
Baseboard Space Heaters
Bathroom Fans
Blowers (Portable Utility)
Camp, Fish, Hunt & RV
Ceiling Fans (Commercial/Ind.)
Church Baptistry Heaters
Clearance & Specials
Comfort Space Heaters
Construction Heaters
Controls & Transformers
Drum Blowers (Portable)
Evaporative Coolers
Fans/Blowers/Ventilation
Floor Warming Mats/Cables
Garage & Shop Heaters
Garden & Outdoor Items
Hand Dryers (Washrooms)
Heaters & Accessories
Heating Cable & Mats
High Temperature Insulation
High Temp. Wire & Acces.
Industrial Heating Products
Infrared Radiant Heaters
Lighting & Flashlights
Loading Dock Fans
Manufacturers (Vendors)
Nichrome Wire Coils & Acc.
Patio Heaters (Radiant)
Pipe Trace Freeze Protection
Portable 120V Space Heaters
Portable 240V Space Heaters
Replacement Repair Parts
Roof & Attic Ventilators
Roof & Gutter Deicing Cable
Snow & Ice Removal
Tapes (Adhesive)
Temperature Sensors
Thermostats & Accessories
Tools, Glue, Lights & Gear
Unit Heaters (Blower)
Wall Exhaust Fans
Wall Heaters (Fan-forced)
Wall Panel Convectors
Water Heaters (Tankless)
Whole House Fans
ITEM # QTY.
Results
You searched for: ETI Snow Switch Model APS-3C. Automatic Snow/Ice Melting System Control
Results Displayed: 1 - 4 of 4

ETI Snow Switch Model APS-3C. Automatic Snow/Ice Melting System Control


Description



The APS–3C Snow Switch when used with compatible sensors automatically controls snow/ice melting heaters, ensuring minimum operating costs. Typical applications include pavement, sidewalk, loading dock, roof, gutter and down spout snow/ice melting. The APS–3C is interchangeable with earlier APS–3 models.

The adjustable hold-on timer continues heater operation for up to 10 hours after snow stops to ensure complete melting. The optional RCU–3 Remote Control Unit can be located where system operation can be conveniently observed. It duplicates many of the controls and indicators on the APS–3C front panel. It is used to clear tracked and drifting snow that may not land on a sensor.

The calibrated 40°F to 90°F (4°C to 32°C) high limit thermostat prevents excessive temperatures when using constant wattage and MI heaters. It also permits safe testing at outdoor temperatures too high for continuous heater operation. The temperature sensor is included.

The APS–3C provides a relay closure interface for use with energy management computers (EMC). This feature can also be used for general purpose remote control and annunciation and other advanced applications.

All sensor and communications wiring is NEC Class 2. This simplifies installation while enhancing fire and shock safety. The APS–3C can interface up to six sensors from the CIT–1 product family. More sensors provides superior performance by better matching the controller to site performance requirements.


Specifications

General

Area of use
Nonhazardous locations

Approvals
cULus


Enclosure

Protection
NEMA 3R

Cover attachment
Hinged polycarbonate cover, lockable

Entries
3 × 1-1/16" entries

Material
Polycarbonate

Mounting
Wall mounted


Control

Supply
ETI PN 22470: 120 VAC, 50/60 Hz, 35 VA
ETI PN 22471: 208-240 VAC, 50/60 Hz, 35 VA

Load
ETI PN 22470: 120 VAC, 24 amp max. inductive
ETI PN 22471: 240 VAC, 24 amp max. inductive

Contact type
Form C

Maximum Ratings
Voltage: 240 VAC
Current: 24 amps

Heater hold-on timer
0 to 10 hours; actuated by snow stopping or toggle switch

System test
Switch toggles the heater contact on and off. If temperature exceeds high limit, heater cycles to prevent damage.


Snow/Ice Sensors

Sensor type
Up to 6 sensor from the CIT–1 product family

Circuit type
NEC Class 2

Lead length
Up to 500' (152m) using 18 AWG 3-wire jacketed cable
Up to 2,000' (609m) using 12 AWG 3-wire jacketed cable


High Limit Thermostat

Adjustment range
40°F to 90°F (4°C to 32°C)

Dead band
1°F (0.6°C)

Sensor type
Thermistor network

Circuit type
NEC Class 2

Lead length
Up to 500' (152m) using 18 AWG 2-wire jacketed cable
Up to 1,000' (504m) using 12 AWG 2-wire jacketed cable


Energy Management Computer (EMC) Interface

Inputs
OVERRIDE ON (10 ma dry switch contact)
OVERRIDE OFF (10 ma dry switch contact)

Outputs
SUPPLY (10 ma dry switch contact)
SNOW (10 ma dry switch contact)
HEAT (10 ma dry switch contact)
HIGH TEMP (10 ma dry switch contact)
ALARM (10 ma dry switch contact)


Environmental

Operating temperature
-40°F to 160°F (-40°C to 71°C)

Storage temperature
-50°F to 180°F (-45°C to 82°C)

















Installation Instructions
Data Sheet
Item CodeDescriptionVendorQuantity
ETI21357
RCU-3 Remote Control Unit
ETI (Environmental Technology Inc.) Flush or surface mount remote control & indication of Snow/Ice Melting Controllers (for use w/ PD Pro, RS Pro, APS-3C or EUR-5A)
ETI
ETI22471
APS-3C 208/240V Snow Melting Control
ETI (Environmental Technology Inc.) Snow Switch. Automatic Snow/Ice Melting System Control, 208-240 VAC Single Phase, U-L / CSA
ETI
ETI22470
APS-3C 120V Snow Melting Control
ETI (Environmental Technology Inc.) Snow Switch. Automatic Snow/Ice Melting System Control, 120 VAC Single Phase, UL / CSA
ETI
ETI19272
19272 Temperature Sensor
ETI (Environmental Technology Inc.) Ambient High Temperature Sensor with 20 Foot Lead for use with SST-2, SST-3, EUR-5A, APS-4C, SC-40C, APS-3C & GPT-3
ETI